Extended Product Type: XT2S 160 MA 80 Im=480...1120 3p F F

Product ID: 1SDA067768R1

Long Description: C.BREAKER TMAX XT2S 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 80 A I3=480...1120 A
1486635070
Extended Product Type: XT2S 160 MA 80 Im=480...1120 3p F F Product ID: 1SDA067768R1 Long Description: C.BREAKER TMAX XT2S 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 80 A I3=480...1120 A
MS132-10T
1SAM340000R1010
MS132-10T Circuit Breaker for Primary Transformer Protection
The circuit breaker for transformer protection MS132-10T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 10 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
1494940166
MS132-10T 1SAM340000R1010 MS132-10T Circuit Breaker for Primary Transformer Protection The circuit breaker for transformer protection MS132-10T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 10 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
A50-30-00 220-230V 50Hz / 230-240V 60Hz
1SBL351001R8000
3471522081803
A50 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available
1493814349
A50-30-00 220-230V 50Hz / 230-240V 60Hz 1SBL351001R8000 3471522081803 A50 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available
AF52-30-00-11
1SBL367001R1100
AF52-30-00-11 24-60V50/60HZ 20-60VDC Contactor
AF52 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.
1493379077
AF52-30-00-11 1SBL367001R1100 AF52-30-00-11 24-60V50/60HZ 20-60VDC Contactor AF52 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.
PSTX300-600-70
1SFA898114R7000
Softstarter PSTX300-600-70 for max 600V main voltage and 100 - 250V 50/60Hz control supply voltage.
1494246525
PSTX300-600-70 1SFA898114R7000 Softstarter PSTX300-600-70 for max 600V main voltage and 100 - 250V 50/60Hz control supply voltage.

Our timings

[IS_BIZ_OPEN] Mon: 10:30AM  -  8:30PM
[IS_BIZ_OPEN] Tue: 10:30AM  -  8:30PM
[IS_BIZ_OPEN] Wed: 10:30AM  -  8:30PM
[IS_BIZ_OPEN] Thu: 10:30AM  -  8:30PM
[IS_BIZ_OPEN] Fri: 10:30AM  -  8:30PM
[IS_BIZ_OPEN] Sat: 10:30AM  -  8:30PM
[IS_BIZ_OPEN] Sun: Closed  -  Closed

Contact

590/4b Rajmata Complex, Opposite Jijamata Baug, Budhwar Peth, Budhwar Peth, , Maharashtra 411002
+91 8079442803  or   or   
Please keep or 0 before the
number when you dial.
Share Tweet
18.5112538324534 73.860713369342 Indian Electro Trade 590/4b Rajmata Complex, Opposite Jijamata Baug, Budhwar Peth, Budhwar Peth, , Maharashtra 411002
False

SUBSCRIBE

5881a064308e540a084efa37INDIANELECTROTRADEPUNE57c3c1a65d64370d7cf4eb17